Microminiaturized bar code reader with built-in decoder, smaller than half size of a name cards
Various manufacturing lines such as semi-conductor manufacturing, warehousing distribution systems or robotic lines with automated bar code readers, need the small and lightweight sensor-like bar code readers like NEC Infrontia's BCR2600.


Specifications
BCR2660 Series
|
Model |
BCR2662-TA |
BCR2666-TA |
BCR2672-TA |
BCR2676-TA |
| Readable bar codes |
|
|||
|
Number of digits |
1 to 32 digits |
|||
|
Min. resolution |
0.15mm (5.9 mils) |
0.25mm (9.8 mils) |
||
|
PCS value |
0.7 or more (white reflection 85% or more) |
|||
|
Depth of field * |
90mm+50,-40 (3.5 in+2.0,-1.6) |
180mm }50 (7.1 in }2) |
||
|
Max. bar code |
70mm (3.5 in) ** |
100mm (4.3 in) *** |
||
|
Access time |
20 ms |
|||
|
Reading direction |
In both upper and lower directions |
|||
|
Reading start method |
Inzone signal from an external device (no-voltage contact of open collector) |
|||
|
Operating temperature |
0 to 40C (32 to 104F) |
|||
|
Operating humidity |
20 to 90% (non-condensing) |
|||
|
Storage temperature |
-20 to 70C (-4 to 158F) |
|||
|
Storage humidity |
20 to 90% (non-condensing) |
|||
|
Max. external illumination |
6000 lux or less |
|||
|
Installation location |
Indoor |
|||
|
Interface |
RS-232C |
RS-485 |
RS-232C |
RS-485 |
|
Scan beam pattern |
Raster scan **** or Single scan |
|||
|
Scan speed |
100 scans/sec |
|||
|
Direction of beam irradiation |
Side ejection or front ejection |
|||
|
Safety standard for laser |
Class 2 (output 1.0 mW or less) |
|||
|
Transmission speed |
1200, 2400, 4800, 9600 baud (BCR262-TA) |
|||
|
Cleanliness |
Class 1 (0.1 ? m) |
|||
|
Power source |
+5VDC |
|||
|
Dimensions (mm (in)) |
Side ejection: 61.5D x 40W x 25H (2.5 x 1.6 x 1.0) |
|||
|
Weight |
100g (3.5 oz) |
|||
|
Accessories |
Mounter, Screw (M3 x 10) |
|||
Exclusive Power Units
|
Model |
BCV5100 |
BCV5080 |
|
Input voltage |
100V to 240V |
100VAC}10% |
|
Input frequency |
50/60 Hz |
|
|
Dielectric strength |
1.5 kVA, 1min. |
0.5kVA, 1min |
|
Insulation resistance |
50M W or more |
|
|
Operating temperature |
0 to 40C (32 to 104F) |
|
|
Operating humidity |
20 to 90% (non-condensing) |
|
|
Storage temperature |
- 20 to 70C (-4 to 158F) |
|
|
Storage humidity |
20 to 90% (non-condensing) |
|
|
Dimensions |
42.5 x 72 x 182 mm HWD |
32 x 94 x 110 mm HWD |
|
Weight |
2 kg or less |
600g |
|
Accessories |
Connector for BCR2600 |
Connector for commercial power |
|
Connector for interface |
||
|
Connector for in-zone |
||
|
Connector for controller |
||
|
Connector for commercial power |
||
Controller (Optional)
|
Model |
BCC2600 |
|
|
Host interface |
Synchronous system |
Start-stop (RS-232C) |
|
Transmission method |
Half-duplex |
|
|
Transmission speed |
1200 to 9600 baud (adjustable) |
|
|
Transmission code |
In conformance to JIS (7 units) |
|
|
Reader interface |
DENSEI standard network interface (according to the Provision for NDS data transmission) | |
|
Max. number of readers to be connected : 31 units |
||
|
Max. transmission distance : 1km (0.6 mi) |
||
|
Input voltage |
5VDC }5% |
|
|
Input current |
100mA or less |
|
|
Display |
20 digits x 2 lines, LHD, ANK indication |
|
|
Number of keys |
16 keys |
|
|
Operating temperature |
0 to 40C (32 to 104F) |
|
|
Operating humidity |
20 to 90% (non-condensing) |
|
|
Storage temperature |
-20 to 70C (-4 to 158F) |
|
|
Storage humidity |
20 to 90% (non-condensing) |
|
|
Dimensions |
30 x 130 x 150mm (1.2 x 5.1 x 5.4 in) |
|
|
Weight |
620g (1.4 lbs) |
|
|
Accessories |
Connector for interface |
|
Connecting Cables
|
Devices to be connected |
Cable length |
Type of cables |
|
| Between BCR2660 and exclusive power unit | 4.7m max. | Gauges 24 or less AWG (with shield) | |
| For Interface | Between RS-232C and exclusive power unit | 15m (49.2ft) or less (between BCR2660 and exclusive power unit) | Gauges 26 or less AWG (with shield) |
| Between exclusive power unit and exclusive power unit - controller | 1 km (0.6 mi) max. (between BCR2660 and exclusive power unit) | Gauges 28 or less AWG (with shield) | |
| Between inzone sensor and exclusive power unit | 3m (9.8 ft) max. | Gauges 26 or less AWG (with shield) | |
| Between Controller and exclusive power unit | 3m (9.8 ft) max. | Gauges 26 or less AWG (with shield) | |
| Between exclusive power unit and commercial power source | 3m (9.8 ft) max. | Gauges 22 or less AWG (with shield) | |